Theta Industries, Inc. Presents:

Theta DilaSoft I Software

Graphic Map


DilaSoft version 2.75.x is shipping now! See the Updates page for more info.

See the Comparison page for a brief description of what is not included in the Lite version.
See the DilaSoft Updates page for current additions and fixes.
For addition documentation, see the software docs page.

DilaSoft version 2.75.x for Windows.

Some of the new features include:

DilaSoft version 2.69.x for Windows.

Some of the new features include:

DilaSoft for Windows is now shipping for the Dilatometer, DTA/TGA, Parallel Plate Viscometer, Bending Beam Viscometer and Rotating Viscometer.
Available now from Theta Industries, Inc.


DilaSoft I for Windows

Windows Software for Theta Dilatometers, Thermal Analysis; Rotating, Parallel Plate and Bending Beam Viscometers.

Our software is constantly being updated and improved. See the New Features for the latest additions. If you need something special or have a suggestion, please contact Theta Industries! Also check the DilaSoft Updates page for current additions and fixes. For addition documentation, see the software docs page. See the Comparison page for a brief description of what is not included in the Lite version.



Individual program segment alarms
Temperature Program Cycling
Mini-Status Window
Furnace Preheat
Delayed Start
New Automatic Load Cell!

Specimen lengths up to 4 inches (100mm)
Auto Specimen Length!
Auto Data Names!
Data Correction Files!
Theta instruments and DilaSoft software offer the user the most control, options, precision, ease of use, repeatability, flexibility, correction and stored data information than any other instrument on the market!
And if our system does not do something you need, ask us and we'll work it out with you!

Note: The following displays show the Dilatometer version of the software. Versions for other instruments are very similar.

Theta's DilaSoft I software features multiple interactive run-time graphics displays in a multitasking environment allowing an experiment to run while simultaneously analyzing previous experiment data.

The Main Menu is shown below. All instrument options are set through this menu program and the experiment is started from here.

Main Screen

The temperature program editing window displays the versatility and features available for this controlling feature of DilaSoft software. Displayed are the current program segment along with the previous segment at the top and the next segment at the bottom.

The Report Generator automatically gathers all the data about the experiment including the materials, temperature program, tables, dates, graphs and data and formats them into user selectable reports that can be saved to disk files for later use or printed immediately on the default Windows printer.

 

The run-time display shows all important information as the experiment progresses. The displays include: real-time bar graphs of both setpoint and specimen temperatures, strip chart recorder of expansion and temperature, temperature segment profile and much more. While the experiments are running, interactive graphs can be displayed showing expansion vs. temperature and/or expansion vs. time vs. temperature. Graph content varies according to the equipment being used. These graphs can be moved, sized and scaled while the experiment continues to run, giving the operator all necessary information about the experiment as it is taking place.

 

 

The Mini-Status window displays all the same information in a much smaller space, allowing other run-time graphs to be displayed without sacrificing screen space or viewed data.

 

4-Head Mini Display window just for multi-head dilatometers. This new mini window displays the temperature, position and expansion for all 4 heads at the same time, constantly updated and able to be positioned anywhere on the screen.

Data analysis remains unsurpassed in the industry offering the widest array of tools, charts, graphs, tables, printouts and reports. Analysis graphs and reports can all be completely customized by the user, printed immediately or saved to disk files for later retrieval.


Note: the Report and Analysis portions of the software are not available in the Lite version.
See the Comparison page for a brief description of what is not included in the Lite version.

Theta Industries has been the industry leader in thermal testing for over 30 years. We remain dedicated to bringing our customers the finest in both software and hardware to create the most advanced thermal testing equipment available.

For information about the price and availability of Theta's latest software and equipment offerings, call, write, Fax or E-mail to the address below for a prompt response.


New Features

See the DilaSoft Updates page for the most current additions and fixes.

Jump to segment

While an experiment is running, the user can now jump to any segment in the temperature program. this allows going back to an earlier segment for more data or to a later segment to end the experiment sooner.

Individual temperature program segment alarms

Every single temperature program segment (up to 100) can now have an alert alarm set. The two type of alarms are Timed and Timed with Pause. The Timed alert displays the alert window for the amount of time specified in the segment. The Timed with Pause displays the alert window for the specified time and also pauses program operation. Both alerts have audio/voice alerts.

User entered reference materials.

User entered reference materials can now be used in place of the standard reference materials supplied with the software. The list of materials can be saved and loaded independantly of the main software setup to allow changing the list of materials for different instruments.

Change-Over Height (or Deflection) for Viscometers

Change-over height (or deflection) for Parallel Plate and Bending Beam viscometers jumps to the next temperature program segment when the set value is reached..

Standard reference materials for Viscometers

Now includes 3 standard reference materials plus oil for the Rotating Viscometer.

Find Top of Melt for Rotating Viscometer

This feature will alert the user and pause the software, allowing time to precisely find the top of the specimen melt to adjust the depth of the rotor.

Temperature Correction files for Viscometers

This feature allows real-time data correction using temperature vs log of viscosity.

Temperature Program Cycling

Cycling allows program segments to be repeated up to 999 times for cycling tests. See the documentation for Program Cycling, in PDF format.

Mini-Status window

Displays all the information from the Main Status Window but in a much more compact space to save on screen space.

New 4-Head Mini Display

This window is just for multi-head dilatometers. This new mini window displays the temperature, position and expansion for all 4 heads at the same time, constantly updated and able to be positioned anywhere on the screen.

Delayed Start

Great new feature that allows delaying the start of an experiment until a pre-set time.

Preheat the furnace

A new feature that allows pre-heating the furnace to a set temperature before an experiment starts. Very useful for thermocouples that do not return valid temperatures below a certain temperature. No more manually heating up the furnace!

Run-time priority can now be set

The software now has two available priorities for the run-time program. Our 'normal' has been 'high priority'. This can now be set to normal priority to allow more cpu time to other programs.

All new install program!

We now have an all new install program that fixes the minor problem the old installer had with some systems. The new installer is compatible with win95/98, NT and win2000. It's much more reliable and even prettier.

Correction files for both heating and cooling with the same ramp rate!

Correction files have been enhanced to allow using the same ramp rate for both heating and cooling cycles. The correction file documentation has been updated with new information. See the corfile.pdf for more info.

Enhanced graphs!

The run-time graphs can now display data from muti-head systems. The displayed data has increased from 2000 points to 6000 points for greater accuracy.

New Auto Specimen Length!

The auto specimen length feature for Dilatometers allows much faster experiment testing by freeing the operator from measuring the individual specimen lengths. Once set up in Calibration, the software automatically measures and records new specimens when the experiment is started.

New Auto Data Names!

The Auto Data Name feature frees the operator from selecting individual filenames for the saved data file and the experiment information file. This allows much faster repetitive sample testing. D/L or view the Auto Data Name docs.

New Dilatometer correction files!

Correction files guarantee absolute accuracy by measuring the differences of the components making up your particular instrument. View or download the documentation (updated 06/00) for more info.

New automatic load cell operation for the Dilatometers.

Much faster at up to 3 data points per second.

Dilatometer specimen lengths now up to 4 inches (100mm).

True multitasking!

More than one instrument can be operated at the same time from a single computer.

TMA calculations now available in analysis.

Increased resolution of the real-time strip chart display.

"None" can now be selected for the temperature controller, allowing a temperature program to still run and control mass flow valves and head speed while not controlling the furnace temperature.

Y2K Compliant!

A new Run-time Parameter screen allows real-time editing of key experiment parameters like the shrinkage limit, valve difference allowance, torque limits, etc.

Real time editing of the running temperature program allows the user to change the program while an experiment is running.

Proportional mass flow gas valve control.

Audible and visual messages for all warning, error and critical conditions. The software actually announces the messages verbally! And the verbal messages can be translated into any language by the user

For the Rotating Viscometer: Individual rotor speeds can now be set for each individual program segment. The original torque limits control can still be used.

For the Dilatometer: The maximum length a specimen expands to can now be used to calculate the shrinkage limit. This will prevent the meltdown of materials like glass that expands, then rapidly melts.

The Reset/Exit Temperature is now optional, allowing the furnace to remain at any temperature after the experiment is canceled or ends.

The "debug channel" interface has been enhanced to allow setting each channel while in the real time debug screen. This allows the user to see the actual voltages, temperatures, lengths, etc.

Familiar, user-friendly Windows interface throughout affording the flexibility to execute experiments and analyze data simultaneously.

All software features are fully documented in on-line Windows help files, accessible at any time.

Improved temperature profile programming accommodates 100 segments - each with its own data storage interval, valve settings and head speed for more efficient data collection. The entire profile is displayed graphically on screen and can be printed.

Complete display of all instrument configuration options, experiment features and run-time parameters.

User selectable reset temperature for safer experiment shutdown.

Instrument calibration is fully controlled through software. A selectable calibration interval reminds the operator when the equipment requires calibration.

Quick Reports

Automatic reports:

Automatic charts:

Run-time Display

Graphical LVDT positioning for added precision.

Simulated strip-chart recorder displays the last 750 measured position and temperature points in a scrollable, time-based window. It can be turned on or off during the experiment.

Live displays of the current, prior and next temperature program segments, setpoint temperature, actual specimen temperature, valve output and return, etc. The temperature program can be changed while the experiment is running!

Experiment run-time information is continuously updated and can be printed at any time.

Icon-style toolbar permits easy selection of displayable graphs and overall window organization. Graphic icons can be disabled to conserve screen space - all functions remain available through drop-down menus.

Run-time graphs include position vs. temperature, and position and temperature vs. time (content varies by instrument type). Each graph is an independent window which can be moved, sized, printed or closed while the experiment continues executing in the background.

Data Analysis

Compatible with Windows multi-tasking: permits experiments to run in the background while analysis is performed in the foreground.

User-friendly, easy-to-use mouse interface.

Floating toolbar for graphics oriented operations (zoom, point selection, etc).

Multiple windows for graphs and data.

Multiple pre-formatted graphic templates supplied for user convenience.

Automatic TMA and peak detection functions.

User selectable reference/offset temperature.

Temperatures can convert between Celsius, Fahrenheit and Kelvin.

Adjustable data smoothing.

Adjustable decimal points.

Automatic temperature transition point determination and plotting.

Complete Table of Results with user selectable temperature range or row range and increment parameters.

All reports can be viewed, printed or stored as disk files for later retrieval.

 

Request More Information

Theta Industries, Inc. is committed to providing our customers the leading edge of technology, service and support with the finest instruments available.
Phone, fax or write for further information, pricing or upgrade options.



Theta Industries, Inc. 26 Valley Road Port Washington NY 11050 USA

Phone: (516) 883-4088 Fax: (516) 883-4599 E-mail: theta@theta-us.com


Return to home page - - Software - - Dilatometer Listing
Thermal Analysis Listing - - Conductivity Listing - - Viscometer Listing


Click on one of the following to download the demos or flyer.

D/L DTA/TGA DemoD/L Rotating Viscometer DemoD/L Dilatometer Run-time Demo
The following documents are in Adobe Acrobat® PDF format:
D/L or view the Software FlyerD/L or view the Correction File docs.D/L or view the Auto Data Name docs.

D/L or view the Program Cycling docs.

Get Acrobat Reader®

Adobe, the Adobe logo and Acrobat are trademarks of Adobe Systems Incorporated.


This web site is designed and maintained by Bearly Computing.
If you have any comments or questions about the site, please feel free to contact
Rich at: rich@bearlycomputing.com
Last updated on Friday, May 22, 2009

Please note: Theta Industries, Inc. and this web site (www.theta-us.com) are in no way or form affiliated with any religious group or activities.